The dCSS adapter converts 4 standard IRS feeds to 2 dCSS outputs.Terrestrial signals are overlaid onto both output ports. One LED indicator allows the user to monitor the status of the unit. Able to work in legacy, analogue SCR (aSCR) and digital SCR (dSCR) modes.
Features
- Supports SKY Q, Analogue SCR, Legacy, dCSS
- EN50494/EN50607 comms
- Discreet stylised design
- Compatible with all traditional multiswitches
Technical Specifications
INPUTS (ELECTRICAL)
- Input 1 RF frequency range (MHz): Min 88, Max 1950
- Input 2 RF frequency range (MHz): Min 950, Max 1950
- Input 3 RF frequency range (MHz): Min 1100, Max 2150
- Input 4 RF frequency range (MHz): Min 1100, Max 2150
- Impedance: 75Ω
- Nominal input level: 75dBµV
OUTPUT ELECTRICAL
- Nominal impedance: 75Ω
- Return loss: Min 10dB
- Gain variation across band: Max 6dB
- Nominal output level: 80dBµV
CONTROL SIGNALS (LEGACY ONLY)
- Vertical select voltage: Min 11.5V, Max 14.0V, 13V nominal
- Horizontal select voltage: Min 16V, Max 19V, 18V nominal
- Low / High band: 0/22KHz tone
DC SPECIFICATION
- Input voltage: 20V
- Current consumption: 430mA max
- Max supply current (inputs total): 500mA
- Max supply current (inputs per port): 250mA
CONNECTORS
- Input: F x 4
- Output: F x 2
- Power supply: 2.1mm Jack
ENVIRONMENTAL SPECIFICATION
- Operating Temperature: -20°C to +50°C
- Storage temperature: -40°C to +70°C
STANDARDS
- Cenelec: EN 50607
- Cenelec: EN 50494
OPTICAL CABLING
- Fibre type: Single mode
- Standard: GI - approved G657a
DIMENSIONS
- Size (W x H x D): 127mm x 118mm x 38mm
- Weight: 302g (unit only)